Solar Simulation Systems

SS30AAA - 100 Watt Solar Simulator

 

SS30AAA-TP TOUCH PANEL SYSTEM

FEATURES

  • Light intensity feedback for stable light output intensity
  • Computer based Controller
  • Manual / automatic shutter control
  • External lamp alignment with lamp on
  • Manual/Automatic/External/Remote shutter control
  • Forced air cooling
  • Lamp life display
  • Selectable and adjustable constant intensity or constant lamp current
  • Safety Interlock override warning
  • Shutter Status Indicator
  • Lamp status indicator
  • Remote Trouble Shooting via Internet
  • One (1) year factory warranty


SS30AAA-EM ELECTRO-MECHANICAL SYSTEM

FEATURES

  • Light intensity feedback for stable light output intensity
  • Electro-Mechanical Controller
  • Lamp life display
  • External lamp alignment with lamp on
  • Manual/Automatic/External/Remote shutter control
  • Forced air cooling
  • Lamp Life Meter
  • Lamp Current Meter
  • Selectable and adjustable constant intensity or constant power mode
  • Safety Interlock override LED
  • Over Temperature Warning LED
  • Shutter Status Indicator
  • Lamp status indicator
  • One (1) year factory warranty


SS30AAA-TP & SS30AAA-EM TECHINCAL SPECIFICATIONS

Feature Description Specification
Type of Lamp Xenon Short Arc
Lamp Power 100W
Max. Illuminated Area 1.2" (30mm) x 1.2" (30mm)
Light Source Steady State
Air Mass AM1.5G Standard: AM1.5D or AM1 optional
Lamp lifetime 1,500 Hours
Adjustment Range of Light Intensity 100mW/cm2 ±15%
Simulator Class* AAA
Spectral Match to all intervals* ±25% or better
Spatial Non-uniformity of irradiance* ≤ 2% or better
Short Term Temporal Instability (STI)* ≤ 0.5% or better
Long Term Temporal Instability (LTI)* ≤ 2% or better
Dimensions (Height x Width x Depth) 28.4" (722mm) x 11.6" (295mm) x 15.5" (394mm)
Weight 50 Lbs. (22.7 Kg)
The Optimum Working Distance 2.9" (74 mm)
Phase/Voltage/Frequency Single Phase/110-220VAC/50-60Hz
Max. Power Consumption (W) 0.3 KVA

*Meets Class A Requirements of ASTM E927-2010, IEC60904-9 Edition 2.0 2007-10 and JIS C 8912-1998: amendment 1-2005 & Amendment 2-2011