SYSTEM DETAILS
Test Fixture for Solar Simulators with area of illumination ≤ 100mm x 100mm
The I-V Curve Data Acquisition includes a fixture for holding cells for testing (see Figure 1 below). This fixture can accommodate cells from small to up to 100 mm x 100 mm. Adjustable cell stops, in the X & Y-axis, are provided to consistently locate the cells for testing. Two micro-manipulators are provided as shown in Figure 1. Each micro-manipulator has two spring loaded contacts to allow 4-wire measurement even for cells that have top contacts only. Two back-side voltage contacts are embedded in the Plate (galvanically isolated from the Plate) and make good electrical contact when the cell is held down by vacuum to the plate. All voltage and current probes are gold-plated. The cell is held down with vacuum during testing (built-in vacuum pump).
With optional Temperature Control, the cell holding plate can be either cooled or heated in the temperature range of 5-60° C using Peltier cells. Temperature of the plate is measured automatically with accuracy of <±0.5° C and is monitored during cell measurement.


Test Fixture for Solar Simulators with area of illumination ≥ 100mm x 100mm
The I-V Curve Data Acquisition includes a fixture for holding test devices (See Figure 2 below). This fixture can accommodate cells from small to up to 300 mm x 300 mm. Adjustable cell stops, in the X & Y-axis, are provided to consistently locate the cells for testing. For top cell contacting, two bus bars with multiple spring loaded contacting probes (20 per bus bar) are mounted on a frame. The frame can be manually raised to place the cell on the plate for testing. The cell is held down with vacuum (built-in) during testing. After placing the cell in position, the frame can be manually lowered to make probe contact with the cell. Once in the down position, the frame is held down by clasps to maintain contact with the cell. Optional third bus bar and automatic cell contacting is available upon request.
Two back-side voltage contacts are embedded in the platen (galvanically isolated from the platen) and make good electrical contact when the cell is held down by vacuum to the platen. All of the voltage and current probes are gold-plated. Alternative cell contacting mechanisms are available upon request.
With the optional Temperature Control, Cell Holding Plate can be either cooled or heated in the temperature range of 5-60° C using Peltier cells. Temperature of the platen is measured automatically with accuracy of <±0.5° C and is monitored during cell measurement.
Options for Both Types of Systems


DATA ACQUISITION
The SQM Series Surface Quality Monitors can be interfaced with PETSCANTM (SQM500W) or ROTOSCANTM (SQM600W), integrated data acquisition and three-dimensional graphic systems. The SQM500W System is for scanning flat surfaces whereas the SQM600W System is for scanning the inside or outside surface of a cylinder. These systems are used to scan a part and acquire data from the surface with an OSEE sensor, and generate a color map which displays any variation in surface condition. The software for these systems has very powerful features for displaying data in a graphics format, with ZOOM and PAN capabilities. With these systems it is possible to make NON-VISIBLE contaminants/coatings become VISIBLE through a color mapping technique. The SQM500W or SQM600W System includes an OSEE System, and is a very powerful tool for studying and monitoring the effectiveness of cleaning processes or variation in the thickness of very thin films or coatings. Please refer to the SQM500W or SQM600W brochure for additional information.
MODEL | CC-1 | CC-3 | CC-5 | CC-20 | |
---|---|---|---|---|---|
Max. Current Range (A) | ±1 | ±3 | ±5 | ±20 | |
Keithley Source Meter Model # | 2400 | 2420 | 2440 | 2651 | |
Available Current Ranges | ±1A, ±100mA, ±10mA, ±1mA, ±100µA, 10µA, ±1µA | ±3A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA, 10µA | ±5A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA, 10µA | ±20A, ±10A, ±5A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA, ±10µA, ±1µA, ±100nA | |
Max. Voltage Range (V) | ±20 | ±60 | ±40 | ±40 | |
Available Voltage Ranges | ±20V, ±2V, ±200mV | ±60v, ±20V, ±2V, ±200mV | ±40V, ±10V, ±2V, ±200mV | ±40V, ±20V, ±10V, ±1V, ±100mV | |
Max. Power (W) | 20 | 60 | 50 | 200 | |
Measurement Resolution | 16 Bit | ||||
Measurement Accuracy | Better than 0.5% | ||||
Measurement Mode | Fixed or Auto | ||||
Measurement Time (Light) | < 500ms for stable light (Up to 4s if filtering for light fluctuations required) | ||||
Measurement Time (Dark) | 100-1,000ms | ||||
Maximum Points per Curve | 275 | ||||
Maximum Data Acquisition Speed | 100kHz | ||||
Maximum Cell Throughput | 1,200/Hour (With optional Robotics) | ||||
Phase (Power) | Single Phase | ||||
Voltage (Volts)/Frequency (Hz) | 115/220VAC: 50-60Hz | ||||
Max. Power Consumption (W) | 40 W (Up to 600W With Peltier Cells) |
MODEL |
CC-1 | CC-3 | CC-5 | CC-15 | CC-20 |
---|---|---|---|---|---|
Max. Current Range (A) | ±1 | ±3 | ±5 | ±15 | ±20 |
Available Current Ranges | ±1A, ±100mA, ±10mA, ±1mA, ±100µA, 10µA, ±1µA | ±3A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA, 10µA | ±5A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA, 10µA | ±15A, ±10A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA | ±20A, ±10A, ±1A, ±100mA, ±10mA, ±1mA, ±100µA |
Max. Voltage Range (V) | ±20 | ±60 | ±40 | ±10 | ±10 |
Available Voltage Ranges | ±20V, ±2V, ±200mV | ±60v, ±20V, ±2V, ±200mV | ±60V, ±20V, ±2V, ±200mV | ±10V, ±5V, ±2.5V ±1.25V, ±800mV, ±400mV, ±200mV | ±10V, ±5V, ±2.5V ±1.25V, ±800mV, ±400mV, ±200mV |
Max. Power (W) | 20 | 60 | 50 | 150 | 200 |
Measurement Resolution | 16 Bit | ||||
Measurement Accuracy | Better than 0.5% | ||||
Measurement Mode | Fixed or Auto | ||||
Measurement Time (Light) | < 500ms for stable light (Up to 4s if filtering for light fluctuations required) | ||||
Measurement Time (Dark) | 100-1,000ms | ||||
Maximum Points per Curve | 100-1,000 (model specific) | ||||
Maximum Data Acquisition Speed | 100kHz | 4,096 | |||
Maximum Cell Throughput | 1,200/Hour (With optional Robotics) | ||||
Phase (Power) | Single Phase | ||||
Voltage (Volts)/Frequency (Hz) | 220VAC (115VAC Optional) / 50-60Hz | ||||
Max. Power Consumption (W) | 40 W (Up to 600W With Peltier Cells) | ||||
Curve Correction to STC | IEC 60891, Anderson or Blaessar | ||||
Advance Fitting of I-V Curves | SEM, DEM and VDEM Models (17 Different Weight Functions) | ||||
Thermal Coefficients of Voc and Pm | Standard on All Systems (With Optional Temperature Control) | ||||
Irradiance Monitoring & Correction | Standard on All Systems |